Oil, gas & LNGProject watch

Shijiazhuang refinery seeks three pump-protection valves: November 5 notice catch-up

Curated by valve.market · China
Persistent browser storage is unavailable.
IN BRIEF

The original notice specifies three DN150, Class 600, A105 pump-outlet protection valves. Its November 8 response deadline has passed.

Added: 2026.11.10Source language: Chinese
Industry illustration; not the project site or equipment covered by this notice.
Industry illustration; not the project site or equipment covered by this notice. Image: Dariy P. / Unsplash
Organizations中国石油化工股份有限公司石家庄炼化分公司
Location / scopeShijiazhuang
Announced stageCatch-up: original response deadline passed
01

The story explained

This catch-up retains the original November 5, 2026 announcement date. Sinopec’s Shijiazhuang refining branch invited negotiated procurement for its RTC unit under reference TP20261105-2290-02428. The scope is three pump-outlet protection valves specified as RF, A105, Class 600 and DN150, with required delivery on September 1, 2027.

The buyer requires forged rather than cast bodies, integral non-return functions in both main and bypass paths, and a continuously regulating multistage pressure-reduction bypass trim rather than an orifice-plate arrangement. Factory testing must address main-valve pressure loss, bypass flow and differential pressure, and minimum-flow switching points, supported by test and calculation reports. These are purchasing requirements, not verified performance claims for an awarded product.

Agents and traders are excluded. Licences and type-test documentation must cover the relevant valve category, class and size, and comparable supply references are required. The original document-download and qualification-response deadline was November 8 at 16:40 Beijing time and has passed. The notice establishes an invitation only; it names no winner and provides no evidence of an extension.

02
EDITORIAL INTERPRETATION

Why it matters

The catch-up provides concrete requirements for pump minimum-flow protection in refining service. The expired response window should not be presented as an open opportunity.

Relevant toProject owners, EPC contractors, valve, pump and process-control suppliers

03

What to watch next

Watch for any separately issued extension, clarification or award; final parameters remain subject to technical documents and contract.

These are research prompts, not announced tenders or confirmed subsequent developments.

SOURCE & VERIFICATION

中国石化物资采购电子商务平台

石家庄炼化绿转项目RTC装置用泵保护阀-M1M采购公告

This is an independently written summary and analysis, not an official translation. Project plans and status may change.